About Ober-Read

[ Home ] [Tuthill Pump Guide] [Request Literature] [Application/Quote Request]
Tuthill gear pumps were known as Tutcal Pump.  Tuthill gear pumps are sealless magnetic drive pumps.
Tuthill
D Series
Magnetic Drive Gear Pumps


Flow Range - .11 to 2.3 ml/rev
Flow Rates to 7.3 lpm (.25 to 121 gph)
Differential Pressure to 250 psi (17.2 bar)
System Pressure to 500 psi (34.5 bar)
316 Stainless Steel Pump Body
1/8" or 1/4" NPT Connections
Variable Flow Control Optional

 

Model
( ml/rev)

Flow @ Pressure @ 3500 RPM
GPH @
0 PSI
L/Hr @
0 bar
GPH @
Max. Diff. Pressure
L/Hr @
Max. Diff. Pressure
0.11
6 GPH
23 L/Hr
.2 GPH @ 150 PSI
0.75 L/Hr @ 10.3 bar
0.19
10 GPH
38 L/Hr
.7 GPH @ 250 PSI
2.6 L/Hr @ 17.2 bar
0.23
12 GPH
45 L/Hr
2 GPH @ 250 PSI
7 L/Hr @ 17.2 bar
0.38
20 GPH
76 L/Hr
5 GPH @ 250 PSI
19 L/Hr @ 17.2 bar
0.57
30 GPH
114 L/Hr
9 GPH @ 250 PSI
34 L/Hr @ 17.2 bar
0.68
36 GPH
136 L/Hr
17 GPH @ 200 PSI
64 L/Hr @ 13.8 bar
0.80
42 GPH
159 L/Hr
21 GPH @ 200 PSI
79 L/Hr @ 13.8 bar
0.99
52 GPH
197 L/Hr
36 GPH @ 140 PSI
136 L/Hr @ 9.7 bar
1.2
63 GPH
238 L/Hr
45 GPH @ 140 PSI
170 L/Hr @ 9.7 bar
1.3
68 GPH
257 L/Hr
51 GPH @ 125 PSI
193 L/Hr @ 8.6 bar
1.6
84 GPH
318 L/Hr
68 GPH @ 100 PSI
257 L/Hr @ 6.9 bar
2.0 105 GPH 397 L/Hr 86 GPH @ 100 PSI 325 L/Hr @ 6.9 bar
2.3 121 GPH 458 L/Hr 96 GPH @ 100 PSI 363 L/Hr @ 6.9 bar
Performance Estimate Based on Pumping 77°F (25°C) Clean Water

Specifications:

Temperatures: -50°F to 350°F (-46°C to 176°C)
Viscosities
: 2000 cps+
Magnet Torque
: 240 in/oz, 50 in/oz, and 22 in/oz magnets available *
Magnet Shrouds
: Ceramic Magnets (50 in/oz & 22 in/oz) may be O-Ring sealed shrouded, Samarium Cobalt Magnets (240 in/oz) are Metal Laser Welded
Metal Wetted Parts
: 316 Stainless Steel, Hastelloy C276, or Titanium
Pumphead Material:
316 Stainless Steel
Gear Materials
: PPS (Polyphenylene Sulfide), PEEK (Polyetheretherketone), or Teflon *
Bearing Materials
: PPS (Polyphenylene Sulfide), PEEK (Polyetheretherketone), Carbon, or Glass filled Teflon *
O-Rings
: Viton, Teflon, EPR (Ethylene Propylene Rubber), Nitrile, or Neoprene *
Ports
: 1/8" NPT or 1/4" NPT *
Suction Vacuum
: Pumps self prime when wetted with operating fluid to 28.5 Hg" (724mm Hg). Dry lift not recommended. Fluid viscosity, temperature and pressure may affect the performance.
Bypass
: Full flow externally adjustable Bypass option available. Adjustment may be performed while pump is operating. The function of the Bypass is to prevent over pressurization of the system as it acts as a relief valve that permits re
-circulation of the pumped medium when the Bypass pre-set pressure is reached. The Bypass can prevent motor overload and often eliminates the need for costly external Bypass plumbing and prevents decoupling if differential pressures exceed design limits. Bypass is factory set. Low and high pressure options available.
Operating Temperatures above 140° F (60° C)
In the D Series Product line we offer special sizing option for operating at temperatures above 140° F (60° C). Below is a chart for selecting the option letter for the 17th position of the model number for specifying your operating temperature.

Letter

° C

° F

Letter

° C

° F

B

61-70

141-158

F

101-120

213-248

C

71-80

159-176

G

121-140

249-284

D

81-90

177-194

H

141-160

285-320

E

91-100

195-212

J

161-180

321-356

Gear & Bearing Material Temperature Limit

PPS limit is approximately 250° F (121° C)
Carbon and PEEK limits are approximately 350° F (176° C)
If possible, for temperatures above 250° F (121° C) Carbon bearings should be selected.

*Contact us for other options available

Tuthill D Series Specification Page

Tuthill D Series Model Numbering Guide

Motor Options Page

Product Instruction Manuals