Model |
Flow @ Pressure @ 3500 RPM
|
|||
|
GPH @
0 PSI |
L/Hr @
0 bar |
GPH @
Max. Diff. Pressure |
L/Hr @
Max. Diff. Pressure |
|
|
0.11
|
6 GPH
|
23 L/Hr
|
.2 GPH @ 150 PSI
|
0.75 L/Hr @ 10.3 bar
|
|
0.19
|
10 GPH
|
38 L/Hr
|
.7 GPH @ 250 PSI
|
2.6 L/Hr @ 17.2 bar
|
|
0.23
|
12 GPH
|
45 L/Hr
|
2 GPH @ 250 PSI
|
7 L/Hr @ 17.2 bar
|
|
0.38
|
20 GPH
|
76 L/Hr
|
5 GPH @ 250 PSI
|
19 L/Hr @ 17.2 bar
|
|
0.57
|
30 GPH
|
114 L/Hr
|
9 GPH @ 250 PSI
|
34 L/Hr @ 17.2 bar
|
|
0.68
|
36 GPH
|
136 L/Hr
|
17 GPH @ 200 PSI
|
64 L/Hr @ 13.8 bar
|
|
0.80
|
42 GPH
|
159 L/Hr
|
21 GPH @ 200 PSI
|
79 L/Hr @ 13.8 bar
|
|
0.99
|
52 GPH
|
197 L/Hr
|
36 GPH @ 140 PSI
|
136 L/Hr @ 9.7 bar
|
|
1.2
|
63 GPH
|
238 L/Hr
|
45 GPH @ 140 PSI
|
170 L/Hr @ 9.7 bar
|
|
1.3
|
68 GPH
|
257 L/Hr
|
51 GPH @ 125 PSI
|
193 L/Hr @ 8.6 bar
|
|
1.6
|
84 GPH
|
318 L/Hr
|
68 GPH @ 100 PSI
|
257 L/Hr @ 6.9 bar
|
| 2.0 | 105 GPH | 397 L/Hr | 86 GPH @ 100 PSI | 325 L/Hr @ 6.9 bar |
| 2.3 | 121 GPH | 458 L/Hr | 96 GPH @ 100 PSI | 363 L/Hr @ 6.9 bar |
|
Performance
Estimate Based on Pumping 77°F (25°C) Clean Water
|
||||
Specifications:
Temperatures: -50°F to 350°F
(-46°C to 176°C)
Viscosities: 2000 cps+
Magnet Torque: 240 in/oz, 50
in/oz, and 22 in/oz magnets available *
Magnet Shrouds: Ceramic
Magnets (50 in/oz & 22 in/oz) may be O-Ring sealed shrouded,
Samarium Cobalt Magnets (240 in/oz) are Metal Laser Welded
Metal Wetted Parts: 316 Stainless Steel, Hastelloy C276, or Titanium
Pumphead Material: 316 Stainless Steel
Gear Materials: PPS (Polyphenylene Sulfide), PEEK
(Polyetheretherketone), or Teflon *
Bearing Materials: PPS (Polyphenylene Sulfide), PEEK (Polyetheretherketone),
Carbon, or Glass filled Teflon *
O-Rings: Viton, Teflon, EPR (Ethylene Propylene Rubber), Nitrile, or
Neoprene *
Ports: 1/8" NPT or
1/4" NPT *
Suction Vacuum: Pumps self
prime when wetted with operating fluid to 28.5 Hg" (724mm Hg). Dry lift not
recommended. Fluid viscosity, temperature and pressure may affect the
performance.
Bypass: Full flow externally
adjustable Bypass option available. Adjustment may be performed while pump is
operating. The function of the Bypass is to prevent over pressurization of the
system as it acts as a relief valve that permits re
Operating Temperatures above 140°
F (60° C)
In the D Series Product line we
offer special sizing option for operating at temperatures above 140° F (60°
C). Below is a chart for selecting the option letter for the 17th
position of the model number for specifying your operating temperature.
|
Letter |
° C |
° F |
Letter |
° C |
° F |
|
B |
61-70 |
141-158 |
F |
101-120 |
213-248 |
|
C |
71-80 |
159-176 |
G |
121-140 |
249-284 |
|
D |
81-90 |
177-194 |
H |
141-160 |
285-320 |
|
E |
91-100 |
195-212 |
J |
161-180 |
321-356 |
Gear & Bearing Material Temperature Limit
PPS limit is approximately 250° F
(121° C)
Tuthill D Series Specification Page